Арт.: 100-K12D200

Контактор миниатюрный IEC 12 А

Контактор миниатюрный IEC 12 А, используется в промышленном оборудовании

Цена по запросу  — уточняйте актуальную стоимость
Lifecycle Status Active
Repair Options Available No
Contact Configuration None,2 N.O./ 2 N.C. Poles
Contactor Size 12 A
Special Features Screw Type Terminals
Sub Brand IEC

Технические характеристики

Lifecycle Status Active
Repair Options Available No
Contact Configuration None,2 N.O./ 2 N.C. Poles
Contactor Size 12 A
Special Features Screw Type Terminals
Sub Brand IEC
Altitude, max 2000 m (NN) per IEC 60947-4
Ambient temperature Storage: -55...80 (-67...176)
Auxiliary contact configuration No auxiliary contact
Auxiliary contacts IP2X
Capacitance, max 750 µF @ short-circuit current of 10 kA
Climatic withstand IEC 60068-2-30
Coil consumption, hold-in Cold 3.0 W, warm 2.6 W DC (conventional)
Coil consumption, pick-up Cold 3.0 W, warm 2.6 W DC (conventional)
Conductor cross section Main contact, 2 conductor: 1...2.5 mm² + 1...4 mm²
DIN fuses (gG, gL) current rating Type 2 (per IEC 60947-4-1): 20A @ 400V, 50 kA available fault current
Features Mini-contactors, Uniform panel mounting dimensions, Panel mounting or mounting on 35 mm DIN Rail, Ma
General purpose current (enclosed) 18 A per UL/CSA
Insulation class of the coil Class F per IEC 60085, Class 105 insulation system per UL 508
Lifespan Mechanical DC control: 15000000 ops
Main current circuit resistance 2.2 mΩ
Number of normally closed contacts as main contact 2
Number of normally open contacts as main contact 2
Operating limits, dropout (0.2...0.75) x Us @ 50 Hz, 60 Hz, 50/60 Hz
Operating limits, pick-up (0.85...1.1) x Us @ 50 Hz, 60 Hz, 50/60 Hz
Operating time, closing delay 6...12 ms DC (conventional)
Operating time, opening delay 8...12 ms with integrated diode
Optional accessories Front-mount auxiliary contacts, surge suppressors, electronic timers, mechanical interlocks
Optional overload relays None
Packaging Single pack (quantity of 1)
Protection class IP2X
Rated control supply voltage at AC 50 Hz 110 V
Rated control supply voltage at AC 60 Hz 120 V
Rated control supply voltage at DC 0 V
Rated current (enclosed) 13.8A @ 115V, 1-phase per UL/CSA
Rated filament current 9A @ 230/240V, AC-5b
Rated impulse withstand voltage (Uimp) 6 kV
Rated isolation voltage (Ui) IEC: 690V, UL, CSA: 600V
Rated operational current (Ie) 4-poles: 20A @ 40°C, AC-1
Rated operational power (Pe) 8.3 kW @ 240V, AC-1 (50 Hz), ambient temperature 40 °C
Rated power (enclosed) 2Hp @ 230V, 1-phase per UL/CSA
Recommended torque 10.6 in-lb
Shock resistance IEC 60068-2
Short time withstand (Icw) 96A @ 10s, 60 °C
Switching of DC loads 2-poles in series: 9A @ 24V (Non-inductive or slightly inductive loads or resistance furnaces DC-1 a
Switching of hermetically sealed cooling compressor motors 18A @ 400V, AC-8a (manual reset of overload release (50 Hz))
Switching of lamps Gas discharge lA, open: 18A @ 40°C, AC-5a
Switching of low inductive loads 20A @ 400V, AC-7a per IEC 61095 (50 Hz)
Switching of motor load 11A @ 400V, AC-7b (50 Hz)
Type of electrical connection of main circuit Screw connection
UL class CC and CSA HRCI-MISC fuses rating 30A @ 600V, 50 kA available fault current per UL 508 and CSA 22.2 No. 14
UL class J and CSA HRCI-J fuses rating 30A @ 600V, 50 kA available fault current per UL 508 and CSA 22.2 No. 14
UL class K5 and RK5 fuses rating 40A @ 600V, 5 kA available fault current per UL 508 and CSA 22.2 No. 14
Vibration resistance IEC 60068-2
Voltage type for actuating AC
Weight DC: 0.2 kg

Запросить цену на Контактор миниатюрный IEC 12 А

Заполните форму — ответим с актуальной ценой и сроком поставки в течение рабочего дня

Похожие позиции